1. Question
1 pointsThe equipment grounding conductor is an energized conductor under normal conditions:
Correct
Incorrect
-
Question 2 of 12
2. Question
1 pointsPower conductors operating at 300V or less that are mounted above communication conductors must have a climbing space of at least _____ :
Correct
Please Refer: OSHA Code 1910.304(c)(1)(iii)
Incorrect
Please Refer: OSHA Code 1910.304(c)(1)(iii)
-
Question 3 of 12
3. Question
1 pointsOutside branch circuits, feeders and service conductors which pass over roofs must be at least _______ above the highest point of the room:
Correct
Please Refer: OSHA Code 1910.304(c)(4)
Incorrect
Please Refer: OSHA Code 1910.304(c)(4)
-
Question 4 of 12
4. Question
1 pointsOpen conductors shall be at ____ above the finished grade, sidewalks, or from any platform or projection from which they might be reached:
Correct
Please Refer: OSHA Code 1910.304(c)(2)(i)
Incorrect
Please Refer: OSHA Code 1910.304(c)(2)(i)
-
Question 5 of 12
5. Question
1 points______ is the conductors and equipment for delivering energy from the electricity supply system to the wiring system of the premises served:
Correct
Incorrect
-
Question 6 of 12
6. Question
1 pointsA Volatile flammable liquid is a flammable liquid having a flash point below ____ degrees F or whose temperature is above its flashpoint:
Correct
Incorrect
-
Question 7 of 12
7. Question
1 pointsThe permanent joining of a metallic parts to form an electrically conductive path which will assure electrical continuity and the capacity to conduct safely any current likely to imposed:
Correct
Incorrect
-
Question 8 of 12
8. Question
1 pointsCommunication circuits that are near to light and power conductors that are operated at over _____ must be provided with a protective device that will stop the current flowing from the power lines through the communication lines:
Correct
Please Refer: OSHA Code 1910.308(e)(2)(i)
Incorrect
Please Refer: OSHA Code 1910.308(e)(2)(i)
-
Question 9 of 12
9. Question
1 pointsThe majority of small bell, buzzer and annunciator systems are Class 2 circuits:
Correct
Incorrect
-
Question 10 of 12
10. Question
1 pointsIn ______ hazard locations, wiring must be within a threaded metal conduit or be of Type MI or MC cable unless flexibility is required:
Correct
Please Refer: OSHA Code 1910.307(b)(A)
Incorrect
Please Refer: OSHA Code 1910.307(b)(A)
-
Question 11 of 12
11. Question
1 points_______ or longer vertical raceway shall be used that connects Dust ignition proof enclosure and the junction box not required to be dust ignition proof which are in Class II location:
Correct
Incorrect
-
Question 12 of 12
12. Question
1 pointsA single receptacle for the pool recirculating pump may be located as close as ______ from the inside wall of the pool:
Correct
Please Refer: OSHA Code 1910.306(j)(2)(i)
Incorrect
Please Refer: OSHA Code 1910.306(j)(2)(i)